The Yanmar YH Series is a range of water-cooled, three-phase diesel generators designed for dependable power generation across commercial and industrial applications. With five generator output classes, open-type and silent-type configurations, and Yanmar diesel engine technology, the series offers options for different power requirements and installation environments.
The YH Series includes the YH170, YH220, YH280, YH440 and YH550 models, with output ratings varying by model and operating frequency. AHCL supports customers across Saudi Arabia with generator enquiries, product guidance, service support and genuine manufacturer spare parts.
The Yanmar YH Series is designed to provide practical diesel power generation for facilities that require a three-phase electrical supply. Its water-cooled, four-stroke diesel engines, radiator cooling system and brushless alternator with automatic voltage regulation (AVR) support generator operation across a range of power requirements.
Available in open-type and silent-type configurations, the series provides flexibility for different installation environments. The silent-type enclosure incorporates sound-insulating construction, while the design includes features intended to simplify daily operation, maintenance access and handling.
The range includes five model classes: YH170, YH220, YH280, YH440 and YH550. Depending on the selected model, frequency and electrical configuration, the standby output ratings extend from 13.4 kVA to 54.7 kVA.
For businesses looking for diesel generators in Saudi Arabia, AHCL can help identify a suitable Yanmar YH Series configuration based on the required output, voltage, operating conditions and installation requirements.
| Specification | Yanmar YH Series |
| Generator type | Diesel generator |
| Available model classes | YH170, YH220, YH280, YH440, YH550 |
| Generator configurations | Open type and silent type |
| Electrical output | Three-phase, four-wire |
| Standby output rating | Approximately 13.4–54.7 kVA across the model and frequency combinations |
| Prime output rating | Approximately 12.5–49.7 kVA across the model and frequency combinations |
| Operating frequency | 50 Hz or 60 Hz, depending on configuration |
| Voltage | Model-dependent; configurations include 380 V and 380/220 V |
| Power factor | 80% lagging |
| Alternator excitation | Brushless AVR |
| Engine type | Vertical, water-cooled, four-stroke diesel |
| Cooling system | Radiator |
| Starting system | Electric starting |
| Fuel | Diesel |
| Engine models | Vary by generator model |
Output ratings, voltage, dimensions, fuel tank capacity and other specifications vary by model, frequency and enclosure type. Confirm the exact configuration and Saudi-market availability with AHCL before ordering.
Key Features
The Yanmar YH Series can be considered for suitable three-phase power requirements in environments such as:
Application note: Generator selection should account for the connected electrical load, motor starting current, required voltage and frequency, operating hours, and whether the application requires prime or standby power. Installation, ventilation, exhaust management and electrical integration must be appropriate for the selected generator and site.
The Yanmar YH Series is a range of water-cooled diesel generators with three-phase, four-wire electrical output. It includes several model classes and open-type and silent-type configurations.
The range lists five model classes: YH170, YH220, YH280, YH440 and YH550. Exact model availability in Saudi Arabia should be confirmed with AHCL.
The standby output ratings range from approximately 13.4 kVA to 54.7 kVA across the models and frequency combinations. Prime output ratings also vary. Confirm the exact rating for the selected model and configuration before specifying a generator for your project.
The open-type configuration has an exposed generator assembly, while the silent-type configuration uses an enclosure incorporating sound-insulating construction. The suitable option depends on the installation environment, ventilation, access and noise-management requirements.
The range offers several output classes for compatible commercial and industrial power requirements. Suitability depends on the electrical load, operating profile, voltage, frequency and exact generator configuration.
Start with the required kVA or kW, voltage, frequency, phase, running load and starting requirements. Also consider whether the generator will operate continuously or provide standby power, the installation environment and the preferred enclosure type. AHCL can help review these requirements.
Contact AHCL’s Auto & Equipment Division for product enquiries, model and configuration confirmation, quotations, service support and genuine manufacturer spare parts.
Yanmar Generator Solutions from AHCL in Saudi Arabia
Abdullah Hashim Company Limited (AHCL), Auto & Equipment Division, serves customers across Saudi Arabia through its branch network. For businesses evaluating Yanmar power generation equipment, AHCL can assist with product enquiries and selection, alongside service support and genuine manufacturer spare parts.
Contact AHCL to discuss your required generator capacity, operating conditions, installation environment and preferred configuration.
Request a quotation for the Yanmar YH Series and confirm the model that meets your project’s power requirements.